1.What is a meter counter for rod straightening machine
The meter counter of the rod straightening machine is an accessory used to calculate the length of the steel bar during the straightening process during the processing of steel bars. The meter counter of the rod straightening machine is also called an encoder.
In the work of adjusting and cutting steel bars, the frequency of use is very high, and the environment is full of iron dust and dust. Although the meter counter is dust-proof to a certain extent, it will inevitably be damaged if it is used for a long time. The user is replacing it with a new one. In the case of the meter counter, the new meter counter has not been calibrated. After installation, the length of the rebar and the actual length are often inaccurate, so at this time, the user needs to calibrate the meter counter.
2.The proofreading method of the original meter counter of the rod straightening machine
The original meter counter of the straightening machine is set and matched with the built-in parameters of the straightening machine. At this time, the length of the cut steel bar is not accurate, which is usually caused by the wear of the straightening machine’s meter wheel. The user only needs to calibrate the straightening machine.
1. Set 20 pieces with a length of 1 meter
2. Stop running after cutting 3 steel bars
3. Measure the actual length of the steel bar that has been cut (the first one is not counted, the actual length of the second and third steel bars are measured), and the length is added or subtracted on the computer board of the rod straightening machine according to the actual length of the steel bar.If the actual length is 95cm, set “length +” “5” on the computer board
4. Run again after cutting 3 pieces and stop running
5. Repeat the third step until the measured length matches the actual length (the error is generally controlled within 0.5cm)
6. Set 10 steel bars over 4 meters to test whether the actual error is within the acceptable range when cutting long steel bars. If the error is within the acceptable range, the proofreading is completed. If the error exceeds the acceptable range, the second type is required Method for more accurate proofreading